Our Products
CGC
Equipment Name:
- Plasma Ozone Generator
- VOCs: 50~60%
- Odor: 50~60%
- Particles: -----
- Dust and oil: -----
- Fumes: -----
- Big airflow (1~1000Nm3/min)
- High concentration of odor and VOCs
Features
Feature
1. Features
3. Principle 4. Application Fields
![]() | ![]() |
- Dual function in once equipment: purify waste gas and water at the same time
- High efficiency of high concentration ozone production
- PSA automatic oxygen generation

3. Principle
The principle of generating Ozone is to let the oxygen molecules go through the high voltage tube, make high energy electrical pulse bumped into the oxygen molecules to dissociate the bond and became to the oxygen atom. Oxygen atoms combine with the other oxygen molecules to become the ozone molecules. The higher concentration of ozone was generated by the pure oxygen. The plasma PSA system produced high concentration ozone to raise the efficiency and reduce costs. The ozone combines with pollutants and stay in the reaction tank for a while. After ozone and pollutants oxidizing, it can decompose CO2, water and nontoxic salts.
Ozone can remove the organic substances in the air and water effectively but doesn’t have the reaction with them. It also has the advantages of no pollution, no remain in the environment.


APPLICATION FIELDS | |||
---|---|---|---|
1 | Chemical Industry | 14 | Screw Industry |
2 | Electro-Optical Industry | 15 | Asphalt Concrete Industry |
3 | Printing Industry | 16 | Pharmaceutical Industry |
4 | Dye Industry | 17 | Metal Casting Industry |
5 | Food Industry | 18 | Semi-Conductor Manufacturing |
6 | Textile Industry | 19 | Manufacturing |
7 | Paper Industry | 20 | Bio-Technology |
8 | Plastic Injection Molding Industry | 21 | Surface Treatment |
9 | Agrochemical Industry | 22 | Metal Manufacturing |
10 | Electronic Components Manufacturing | 23 | Wiring and Cable Manufacturing |
11 | Feeding Processing Industry | 24 | Waste Water Treatment |
12 | Rubber Industry | 25 | Bare Printed Circuit Boards Manufacturing |
13 | Iron and Steel Industry | 26 | Refuse Incineration Plant |
Advantages
1. Comparison of Ozone Generators
2. Comparison of Treatment Principle
Equipment | ![]() Plasma Catalyst Ozone Generator | Conventional Quartz Tube Ozone Generator |
---|---|---|
1. Ozone Concentration | 50,000ppm | 7,500ppm |
2. Treatment Efficiency (the same quantity of ozone) | 80~90% | 25~30% |
3. Annual Maintenance | Dust-proof and Automatic drain (Less maintenance) | Easy to be influenced by dust and vapor, Breakdown problems (More maintenance) |
4. Oxygen Supply | PSA auto supply system | External oxygen cylinder |
5. Power Consumption | 1/3 time | 1 time |
6. Maintenance Expenses (Every 3,600 hours or every year) | 1/2 time | 1 time |
2. Comparison of Treatment Principle
Items | Incineration | Bio-Filters | Plasma Ozone Treatment | Active Carbon Adsorption |
---|---|---|---|---|
1. Cost | The most highest | High | Middle | Low |
2. Annual Operation Fee | The most highest | Low | The most Lowest | High |
3. Follow-up Requirement of Equipment | Replace the Consumables | Biological bacteria culture | No | Replace few Active Carbon |
4. Environmental Protection Standard | Qualified | Qualified | Qualified | Qualified |
5. Annual Average Cost | High | Middle | Low | The most highest |
6. Organic Exhaust Gas Removal Efficiency | >98% | >40% | 50~80% | >80% |
7. Maintenance | Middle | Easy | Easy | Easy |
3. Comparison of Plasma Ozone Purification and Other Techniques
Techniques | Disadvantages | Advantages of Plasma Ozone Purification | |
---|---|---|---|
1 | Concentration+Incineration | (1)High cost of fuel consuming. (2)High boiling point substances of the exhaust influence on adsorption lifetime. (3)Disposal problem. | (1)No fuel consuming. (2)No influence on high boiling point substance. (3) No disposal problem. |
2 | Active Carbon Fluidized Bed System + Condenser System | (1)High temperature and Nitrogen desorption needed. High cost. (2) High boiling point substances of the exhaust influence on adsorption lifetime. (3) Disposal problem. | (1)Operation in low temperature. Low risk. (2)No influence to high boiling point substance. (3) No disposal problem. |
3 | Bio-Filters | Require large installation area. | Require small installation area. |
4 | Activated Carbon Adsorption | (1)Massive consumables need to be replaced constantly. High cost. (2) Disposal problem. | (1) No massive consumables need to be replaced constantly. (2) No disposal problem. |
5 | Wet Scrubber | Waste water problem. | Less waste water. |
6 | Conventional Scrubber | (1) Lower efficiency by using sodium hypochlorite. (2)Concern of generating Chlorinated Organic Compounds. | (1)Higher efficiency by using O3. (2)No concern of generating Chlorinated Organic Compounds. |
Specification
Capacity (g/hr) | 60 | 90 | 120 | 150 | 180 | 240 | 300 | 450 | 750 |
---|---|---|---|---|---|---|---|---|---|
Type | CGC-60 | CGC-90 | CGC-120 | CGC-150 | CGC-180 | CGC-240 | CGC-300 | CGC-450 | CGC-750 |
L (mm) | 600 | 800 | 800 | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 | 1,000 |
W (mm) | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 600 | 1,000 |
H (mm) | 1,300 | 1,600 | 1,600 | 1,700 | 1,700 | 1,700 | 1,700 | 1,700 | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating | ||||||||
Total Weight | 180kg | 220kg | 230kg | 250kg | 270kg | 300kg | 250kg | 280kg | 300kg |
Bump(HP) | 1/2HP | 1/2HP | 1/2HP | 1/2HP | 1/2HP | 1/2HP | 1/2HP | ||
Power Consumption(KW) | 2.3KW | 2.3KW | 3KW | 3.5KW | 3.8KW | 4.5KW | 7.6KW | 10.5KW | 12.5KW |
Reamrks | Dual function (for waste gas and water) |
Feature
1. Features




- Dual function in once equipment: purify waste gas and water at the same time
- High efficiency of high concentration ozone production
- PSA automatic oxygen generation

3. Principle

4. Application Fields The principle of generating Ozone is to let the oxygen molecules go through the high voltage tube, make high energy electrical pulse bumped into the oxygen molecules to dissociate the bond and became to the oxygen atom. Oxygen atoms combine with the other oxygen molecules to become the ozone molecules. The higher concentration of ozone was generated by the pure oxygen. The plasma PSA system produced high concentration ozone to raise the efficiency and reduce costs. The ozone combines with pollutants and stay in the reaction tank for a while. After ozone and pollutants oxidizing, it can decompose CO2, water and nontoxic salts.
Ozone can remove the organic substances in the air and water effectively but doesn’t have the reaction with them. It also has the advantages of no pollution, no remain in the environment.

Application Fields | |
---|---|
1 | Chemical Industry |
2 | Electro-Optical Industry |
3 | Printing Industry |
4 | Dye Industry |
5 | Food Industry |
6 | Textile Industry |
7 | Paper Industry |
8 | Plastic Injection Molding Industry |
9 | Agrochemical Industry |
10 | Electronic Components Manufacturing |
11 | Feeding Processing Industry |
12 | Rubber Industry |
13 | Iron and Steel Industry |
14 | Screw Industry |
15 | Asphalt Concrete Industry |
16 | Pharmaceutical Industry |
17 | Metal Casting Industry |
18 | Semi-Conductor Manufacturing |
19 | Manufacturing |
20 | Bio-Technology |
21 | Surface Treatment |
22 | Metal Manufacturing |
23 | Wiring and Cable Manufacturing |
24 | Waste Water Treatment |
25 | Bare Printed Circuit Boards Manufacturing |
26 | Refuse Incineration Plant |
Advantages
1. Comparison of Ozone Generators
2. Comparison of Treatment Principle
![]() Plasma Catalyst Ozone Generator | Conventional Quarts Tube Ozone Generator |
---|---|
1. Ozone Concentration | |
50,000 ppm | 7,500 ppm |
2. Treatment Efficiency (the same quantity of ozone) | |
80~90% | 25~30% |
3. Annual Maintenance | |
Dust-proof and Automatic drain (Less maintenance) | Easy to be influenced by dust and vapor, Breakdown problems (More maintenance) |
4. Oxygen Supply | |
PSA auto supply system | External oxygen cylinder |
5. Power Consumption | |
1/3 time | 1 time |
6. Maintenance Expenses ( every 3,600 hours or every year) | |
1/2 time | 1 time |
2. Comparison of Treatment Principle
Items | Plasma Ozone Treatment |
---|---|
1. Cost | Middle |
2. Annual Operation Fee | The Lowest |
3. Follow-up Requirement of Equipment | No |
4. Environmental Protection Standard | Qualified |
5. Annual Average Cost | Low |
6. Organic Exhaust Gas Removal Efficiency | 50~80% |
7. Maintenance | Easy |
Items | Incineration |
---|---|
1. Cost | The most highest |
2. Annual Operation Fee | The most highest |
3. Follow-up Requirement of Equipment | Replace consumables |
4. Environmental Protection Standard | Qualified |
5. Annual Average Cost | High |
6. Organic Exhaust Gas Removal Efficiency | >90% |
7. Maintenance | Middle |
Items | Active Carbon Adsorption |
---|---|
1. Cost | Low |
2. Annual Operation Fee | High |
3. Follow-up Requirement of Equipment | Replace active carbon |
4. Environmental Protection Standard | Qualified |
5. Annual Average Cost | The most highest |
6. Organic Exhaust Gas Removal Efficiency | >80% |
7. Maintenance | Easy |
Items | Bio-Filters |
---|---|
1. Cost | High |
2. Annual Operation Fee | Low |
3. Follow-up Requirement of Equipment | Biological bacteria culture |
4. Environmental Protection Standard | Qualified |
5. Annual Average Cost | Middle |
6. Organic Exhaust Gas Removal Efficiency | >40% |
7. Maintenance | Easy |
Specification
Capacity (g/hr) | 60 |
---|---|
Type | CGC-60 |
L (mm) | 600 |
W (mm) | 600 |
H (mm) | 1,300 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 180kg |
Bump(HP) | |
Power Consumption | 2.3KW |
Remarks |
Capacity (g/hr) | 90 |
---|---|
Type | CGC-90 |
L (mm) | 800 |
W (mm) | 600 |
H (mm) | 1,600 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 220kg |
Bump(HP) | |
Power Consumption | 2.3KW |
Remarks |
Capacity (g/hr) | 120 |
---|---|
Type | CGC-120 |
L (mm) | 800 |
W (mm) | 600 |
H (mm) | 1,600 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 230kg |
Bump(HP) | ½HP |
Power Consumption | 3KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 150 |
---|---|
Type | CGC-150 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 250kg |
Bump(HP) | ½HP |
Power Consumption | 3KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 180 |
---|---|
Type | CGC-180 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 270kg |
Bump(HP) | ½HP |
Power Consumption | 3.8KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 240 |
---|---|
Type | CGC-240 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 300kg |
Bump(HP) | ½HP |
Power Consumption | 4.5KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 300 |
---|---|
Type | CGC-300 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 250kg |
Bump(HP) | ½HP |
Power Consumption | 7.6KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 450 |
---|---|
Type | CGC-450 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 280kg |
Bump(HP) | ½HP |
Power Consumption | 10.5KW |
Remarks | Dual function (for waste gas and water) |
Capacity (g/hr) | 750 |
---|---|
Type | CGC-750 |
L (mm) | 1,000 |
W (mm) | 600 |
H (mm) | 1,700 |
Cabinet Material | SECC metal with anti-dust powder coating |
Total Weight | 300kg |
Bump(HP) | ½HP |
Power Consumption | 12.5KW |
Remarks | Dual function (for waste gas and water) |
Files
- CGC-Plasma Ozone Generator Download
Video